The electronic output from a Hall effect sensor gives NPN or PNP output pulses to drive a remote counter, offering 0.1% repeatability over a 30:1 flow range: two built-in LEDs indicate power and each output pulse. With the optional 6 point water calibration, the Titan 800 series offers 1-2% flow accuracy: the flow ranges available cover from 0.05 – 15 Litres/min. Special versions can offer a direct flow switch output, for low flow or cooling flow failure alarm, as are units suitable for high temperature operation at up to 125C.
Low cost plastic flowmeter is accurate
The Titan 800 Series turbine flowmeters are really low cost, non-metallic meters, ideal for measuring aggressive chemicals, and also suitable for ultra-pure water. The PVDF construction accepts 8mm or 12mm hose connections, and is specified for up to 60C and 10bar operation.